Structured Cabling

The foundation every network stands on.

Copper and fiber cabling designed to standards, installed neatly, tested end to end and documented so it stays easy to manage for years.

Copper cabling
Cat6 / 6A
Copper cabling
Fiber backbones
OS2 & OM4
Fiber backbones
Every link
Tested
Every link
End to end
Labelled
End to end

Done once. Done right.

Most network problems start at the physical layer. Poor terminations, untested links and unlabelled patch panels cost time every time something changes.

We plan cabling around how the building is used today and how it will grow, follow TIA-568 and ISO/IEC 11801 practice, and hand over test results and drawings with every project.

What we deliver

Everything, end to end.

Copper cabling

Cat6 and Cat6A for data, voice, Wi-Fi access points and cameras, terminated to patch panels and outlets.

Fiber optic installation

Single-mode and multi-mode fiber for building and campus backbones, with fusion splicing and termination.

Data center cabling

Rack-to-rack, top-of-rack and structured trunks with fiber patch panels and clean cable management.

Racks & containment

Network cabinets, cable trays, ladder racks, trunking, conduits and floor boxes installed to suit the space.

Testing & certification

Copper certification and OTDR or light-source testing for fiber, with a report for every link.

Audits & labelling

Surveys of existing cabling, re-labelling, tidy-ups and as-built documentation for messy network rooms.

How we work

From first call to always on.

  1. Survey

    We walk the site, count outlets and plan routes, rooms and containment.

  2. Design

    We specify cable types, racks and fiber backbones and agree drawings with you.

  3. Install

    Our team runs, terminates and dresses every cable to a clean, consistent standard.

  4. Test & hand over

    Every link is tested and labelled, and you receive reports and as-built drawings.

What you get.

  • A tidy, labelled network room that anyone can work in.
  • Test results for every link, ready for audits and warranties.
  • Capacity planned for future Wi-Fi, cameras and growth.
  • Fewer faults and faster changes when the office moves around.
Typical components
  • Cat6 & Cat6A copper
  • OS2 single-mode fiber
  • OM3 / OM4 multi-mode fiber
  • Fusion splicing
  • OTDR testing
  • Fluke copper certification
  • Fiber patch panels
  • Floor-standing & wall racks

Questions, answered.

Should we choose Cat6 or Cat6A?

Cat6 suits most offices today. Cat6A supports 10 Gb/s over the full 100 m and is a good choice for Wi-Fi 6/7 access points and long-term projects.

When do we need fiber instead of copper?

Fiber is used for backbones between floors and buildings, for runs longer than 100 m and for high-capacity links in data centers.

Do you test and document the installation?

Yes. Every link is tested and labelled, and we hand over test reports and as-built drawings at the end of the project.

Can you fix or re-organise existing cabling?

Yes. We audit existing cabling, replace faulty links, re-label and tidy racks without long outages.

Do you work in occupied buildings?

Yes. We plan work in phases or outside business hours to keep disruption low.

Start with solid cabling.

Share your floor plan or site details and we will plan the cabling and give you a clear proposal.